Grab latest NICET ITFAS-Level-1 Dumps as PDF Updated on 2025 [Q33-Q47]

Rate this post

Grab latest NICET ITFAS-Level-1 Dumps as PDF Updated on 2025

Newly Released ITFAS-Level-1 Dumps for Inspection and Testing of Fire Alarm Systems Certified

Q33. According to NFPA 72, manual fire alarm boxes shall be located within which distance of each exit doorway on each floor?

 
 
 
 

Q34. How is a lead-acid battery inspected?

 
 
 
 

Q35. What is the inspection frequency of supervising station alarm system transmitters?

 
 
 
 

Q36. A disconnection of the primary phone line shall cause which of the following events to occur?

 
 
 
 

Q37. What is the maximum travel distance between two fire alarm boxes measured horizontally on the same floor?

 
 
 
 

Q38. Which three of the following branch circuit characteristics are required for circuit identification and accessibility of the fire alarm equipment’s primary power supply? (Choose three.)

 
 
 
 

Q39. When testing initiating devices, what is the maximum allowed time for the supervising station to verify receipt of the signal?

 
 
 
 

Q40. After 15 years from initial installation, all fixed-temperature, nonrestorable heat detectors shall be replaced or have how many detectors per 100 laboratories tested?

 
 
 
 

Q41. According to NFPA 72, which statement is true as it pertains to the testing of audible alarm notification appliances?

 
 
 
 

Q42. Secondary power for the fire alarm primary power supply shall be tested under which load?

 
 
 
 

Q43. A single open fault, in a Class A pathway, shall result in the annunciation of which of the following signals?

 
 
 
 

Q44. Notification appliances in a fire alarm system produce a distinctive evacuation signal that does which of the following?

 
 
 
 

Q45. Which two of the following are needed to perform a periodic test of a projected beam type smoke detector? (Choose two.)

 
 
 
 

Q46. After the secondary power supply has operated the fire alarm system under quiescent load,the secondary power shall be capable of operating all alarm notification appliances for which length of time?

 
 
 
 

Q47. The flash rate of visible notification appliances shall be a minimum of how many flashes per second?

 
 
 
 